- Tension sensor TSB2 with integrated measuring amplifier and high accuracy of 1 % FS
- Various roller widths from 15 mm up to 100 mm, according to the application are available. The roller width should correspond with the width of the material to be measured
- Various output signals are available:
– analog: 0 – 1 V DC (standard), 0 – 10 V DC (optional)
– current: 4 – 20 mA (optional)
– analog DMS: mV/V (optional) - Easy installation, even afterwards, on existing machines
- Easy calibration to customized material by operator – zero and gain calibration is required
- Measuring principle – load cell with high quality strain gauge bridge
Standard Features
- Tension sensor with zylindrical tape roller, ball-bearing mounted
- Tension sensor TSB2 with rugged aluminum housing
- Required power supply +15…24 V DC (regulated)
- Certificate of Compliance with the order 2.1 according EN 10204 is included
- Optionally available: Inspection Certificate 3.1 according EN 10204 with calibration report
Available Models
Model | Tension Range* |
Roller Width |
TSB2-500 | 0 – 500 cN | 20, 30, 36, 41, 50, 100 mm |
TSB2-1000 | 0 – 1000 cN | 20, 30, 36, 41, 50, 100 mm |
TSB2-2000 | 0 – 2000 cN | 20, 30, 36, 41, 50, 100 mm |
TSB2-5000 | 0 – 5000 cN | 20, 30, 36, 41, 50, 100 mm |
TSB2-10K | 0 – 10 daN | 15, 20, 30, 36, 41, 50, 100 mm |
TSB2-20K | 0 – 20 daN | 15, 20, 30, 36, 41, 50, 100 mm |
TSB2-50K | 0 – 50 daN | 15, 20, 30, 36, 41, 50, 100 mm |
TSB2-100K | 0 – 100 daN | 15, 20, 30, 36, 41, 50, 100 mm |
Andere Messbereiche und Messkopfbreiten auf Anfrage.
Other measuring units available, such as g or kg.
* SCHMIDT calibration material depending on tension range and roller width
Important for your order:
Please specify model and roller width! All 3 rollers are small dual-flanged.
Calibration to customized material:
If process material differs significantly from the SCHMIDT calibration material in dimension, rigidity or shape, special calibration using customer supplied samples is recommended. For this purpose a material sample of about 5 m should be supplied.