Special Features
- Amplifier SCV-1 for connecting one sensor with mV/V output
- DIN EN 60715 top hat rail box for snap in installation for mono rail track 17.5 mm
- Various output signals are available:
– analog 0 – 1 V (standard)
– analog: 0 – 10 V DC (optional)
– current: 4 – 20 mA (optional) - Easy calibration to customized material by the operator – zero and gain calibration is required for the connected sensor
Standard Features
- Required power supply +15…24 V DC (regulated)
- CE certified with sensor connected
Available Models
Modle | Connectable Sensors | Output signal |
SCV-1 | Sensors without amplifier (mV/V) | Standard: 0 – 1 V Optional: 0 – 10 V DC, 4 – 20 mA |