FEATURES
Features
Provides 11 channels (a single channel consists of a primary input, a backup input, and an output) on a single unit.
Relays are used to switch between the primary signals and backup signals of channels 1 and 2. High-speed electronic switches are used to switch between the primary signals and backup signals of channels 3 to 11. For LTC, switching is possible between primary signals and backup signals for three inputs.
The input signal type can be selected. On channels 1 and 2, you can select SDI signals (3G, HD, SD), NTSC/PAL black burst signals, or HD3 tri-level sync signals. On channels 3 to 8, you can select NTSC/PAL black burst signals or HD3 tri-level sync signals. Channels 9 and 10 are exclusive to AES/EBU digital audio signals. Channel 11 is exclusive to word-clock signals (TTL input). LTC channels are exclusive to LTC signals (2 Vp-p differential input).
LTC channels provide three systems of two inputs (primary and backup) and three systems of one output. In addition, an LTC cable (sold separately) can be used to connect to a LT 4610 (Sync Generator).
A delay for starting the fault detection at power up can be set to approximately 1 minute or approximately 4 minutes depending on the rise time of the system signal source that the LT 4448 is connected to.
Redundant power supplies are available for increased reliability. Alarms are generated when errors occur.
Combination with two LT 4610s
Combination with two LT 4600As
Rear Panel